Multi-Functional Boiler Water Treatment for Hard & Soft Water Systems – 6050 Bottle

Packaged in cases containing 4 x 5.5kg bottles.

Each case weighs 21.8kg.

Description

Accepta 6050 is a high performance, highly concentrated multi-functional solid chemical boiler water treatment product scientifically formulated for the treatment and protection of boiler systems operating under both hard and soft water conditions.

Accepta 6050 is a solid multi-purpose boiler water treatment product incorporating corrosion inhibitors, scale control agents, alkalinity builders, and a condensate corrosion inhibitor.

Accepta 6050 is suitable for use in boiler systems under both softened and hard water make-up applications. For hard water applications, less than 20 ppm total hardness in the feed water.

All components of Accepta 6050 conform to US FDA Title 21, Section 173 Boiler Water Additives. Accepta 6050 is also an NSF approved product.

Accepta 6050 is available in fully recyclable plastic bottles each containing 5.5kg of concentrated solid chemical.

Accepta 6050 is packaged in cases containing 4 x 5.5kg bottles.

Each case weighs 21.8kg.

Product Benefits

  • Innovative solid chemical technology
  • High performance multi-functional boiler water treatment for hard and soft water systems
  • Incorporates corrosion inhibitors, scale control agents, alkalinity builders, and a condensate corrosion inhibitor
  • FDA approved
  • NSF approved
  • Significant safety improvements
  • Easy to handle, simple to dose
  • Environmentally friendly
  • Reduces carbon footprint
  • Significant space savings

Product Properties

Appearance: Tan to brown amorphous solid
Odour: Slight characteristic odour
Softening point: 43 – 49oC
Bulk density: 1197 kg/m3
Solubility in water: Complete but dissolves slowly
pH (1% solution): 11.5

*Full details of the product properties are available in the Safety Data Sheet. See below.

Application & Dosage Information

1kg of Accepta 6050, dosed at a rate of 80 ppm will treat approximately 27,500lbs of boiler blowdown.

One case of 6050 (21.8kg) is equivalent to 114kg of a conventional liquid product. Comparative values will vary, dependent upon concentration.

Testing & Control

Testing In Boiler Water
In Condensate Return
Total Phosphate (PO4)* 8 – 12 ppm
Sulphite 20 – 30 ppm
p-Alkalinity 250 – 600 ppm
Conductivity See manufacturers guidelines
pH 7.0 – 8.5
Iron <1ppm

* – Total phosphate is used for ease of testing. If the make-up water contains PO4, adjust or lower the control limits to compensate for this interference.

Test kits suitable for monitoring and controlling the use of Accepta 6050 are available from Accepta.

Feeding

Feed Acepta 6050 using an Acepta board system.

It is always advisable to carry out a ‘Control Of Substances Hazardous to Health’ (COSHH) assessment before use.

For further technical assistance concerning Accepta 6050 please contact Accepta.

Safety, Storage & Handling

For full details concerning safety precautions, storage and handling procedures for this product please refer to the latest Safety Data Sheet. To request the latest MSDS for this product please fill out the form below.






Additional information

Weight 25 kg