Multi-Functional Boiler Water Treatment for Soft Water Systems – 6304

You are here:

£610.00 ex. VAT

Available in Bottle or disk form

  • Accepta 6304: 4 x 5.45kg Bottles
  • Accepta 6304D: 8 x 2.25kg Disks

Can be dosed using an Accepta Ultra Feeder Board

Description below

Description

All in One Solid Boiler Treatment

Accepta 6304 is a sulphite based multifunctional boiler water treatment in solid form for softened water make-up application. This is a proprietary boiler water treatment containing catalysed sulphite, high performance sludge & scale conditioning agents and alkalinity builder.

Accepta 6304 contains only ingredients approved under the United States Food & Drug Administration Regulations Title 21, Section 173.310 Boiler Water Additives.

Accepta 6304 is available in 5.45kg jars or 8 x 2.25kg Disks

HOW MUCH TO USE

Accepta 6304 should be dosed to achieve 30-70ppm as sulphite in boiler water or as defined by BS2486:1997 and or manufacturers’ guidelines. 1 case (22kg) is equivalent to 115kg of a conventional liquid product Liquid equivalent comparative values will vary, dependent upon concentration.

Testing In Boiler Water
Sulphite (Sulfite) 30 – 70 ppm
p-Alkalinity 250 – 600 ppm
Conductivity See Manufacturer’s Guidelines

PROPERTIES

Appearance:                 Solid – light brown

Odour:                         mild

pH:                               10  @1%

HANDLING AND STORAGE

Accepta 6304 should be kept away from acids and oxidising agents in a cool dry area. Properly stored, the product will remain effective for 24 – 36 months. Consult Safety Data Sheet for further information

SPILLAGE AND  DISPOSAL

Accepta 6304 is a solid product. In the unlikely event of a spillage, do not allow to enter water course or drains. Small spillages – dilute with plenty of water and wash to waste.

FEEDING

Feed Accepta 6304 using an Accepta board system.

Available in three types:

  • Gravity Fed – No pump needed, requires controller relay or timer
  • Electronic Level Control – Pump needed
  • Mechanical – Pump needed

It is always advisable to carry out a ‘Control Of Substances Hazardous to Health’ (COSHH) assessment before use.

For further technical assistance concerning Accepta 6304 please contact Accepta.

Safety, Storage & Handling

For full details concerning safety precautions, storage and handling procedures for this product please refer to the latest Safety Data Sheet.

To request the latest MSDS for this product please fill out the form below.

Additional information

Weight N/A
Type

AT-6304 Bottle (4 Pack), AT-6304 Disks (8 Pack)

Description

All in One Solid Boiler Treatment

Accepta 6304 is a sulphite based multifunctional boiler water treatment in solid form for softened water make-up application. This is a proprietary boiler water treatment containing catalysed sulphite, high performance sludge & scale conditioning agents and alkalinity builder.

Accepta 6304 contains only ingredients approved under the United States Food & Drug Administration Regulations Title 21, Section 173.310 Boiler Water Additives.

Accepta 6304 is available in 5.45kg jars or 8 x 2.25kg Disks

HOW MUCH TO USE

Accepta 6304 should be dosed to achieve 30-70ppm as sulphite in boiler water or as defined by BS2486:1997 and or manufacturers’ guidelines. 1 case (22kg) is equivalent to 115kg of a conventional liquid product Liquid equivalent comparative values will vary, dependent upon concentration.

Testing In Boiler Water
Sulphite (Sulfite) 30 – 70 ppm
p-Alkalinity 250 – 600 ppm
Conductivity See Manufacturer’s Guidelines

PROPERTIES

Appearance:                 Solid – light brown

Odour:                         mild

pH:                               10  @1%

HANDLING AND STORAGE

Accepta 6304 should be kept away from acids and oxidising agents in a cool dry area. Properly stored, the product will remain effective for 24 – 36 months. Consult Safety Data Sheet for further information

SPILLAGE AND  DISPOSAL

Accepta 6304 is a solid product. In the unlikely event of a spillage, do not allow to enter water course or drains. Small spillages – dilute with plenty of water and wash to waste.

FEEDING

Feed Accepta 6304 using an Accepta board system.

Available in three types:

  • Gravity Fed – No pump needed, requires controller relay or timer
  • Electronic Level Control – Pump needed
  • Mechanical – Pump needed

It is always advisable to carry out a ‘Control Of Substances Hazardous to Health’ (COSHH) assessment before use.

For further technical assistance concerning Accepta 6304 please contact Accepta.

Safety, Storage & Handling

For full details concerning safety precautions, storage and handling procedures for this product please refer to the latest Safety Data Sheet.

To request the latest MSDS for this product please fill out the form below.

Additional information

Weight N/A
Type

AT-6304 Bottle (4 Pack), AT-6304 Disks (8 Pack)

Data Sheets & enquires

To request the safety or technical data sheets on this product or simply enquire further about chemical supply please fill out this contact form.

Contact us

Please complete this form and we will be in touch