Prominent Gamma/X Chemical Dosing Pumps

You are here:

£26.00£1,824.00 ex. VAT

Pumps are available without Degassing heads.

(Contact us to request price and availability for degassing head versions)

Additional Accessories Available:

  • Universal Control Cable
  • Bespoke Prominent Wall Bracket also Available

For export please contact us using the form at the bottom of the page.

PDF data sheets are available below.

Description

Accepta’s range of high performance Prominent Gamma/X dosing pumps are precision manufactured to offer excellent reliability and accurate dosing control of liquids.

Prominent dosing pumps offer external control of the pump output by automatically varying the frequency or number of strokes the pump makes per minute.

The pumps control signal may be by external pacing pulses from a water meter or pH controller with the ability to multiply or divide the pulsed signal.

The gamma/ X solenoid diaphragm metering pump is user-friendly and has a long service life. A sophisticated solenoid control system measures the back pressure present, protects the system from overload and ensures uniform dosing regardless of pressure. In addition, the gamma/ X detects and compensates for air in the dosing head.

Prominent Gamma/X Spec Sheet

 

Prominent Gamma/X Pump Manual

 

Our pumps are supplied fitted with PVDF liquid ends and PTFE seals. This is the most chemically compatible liquid end and is recommended in most cases. Below is the chemical resistance list in case you want to check compatibility with your chemical.

Chemical Resistance List

 

Prominent pumps come with:

Injection fitting (NRV)

Suction foot (NRV)

Suction tube 2m

Injection tube 2m

Powered ON/OFF or Switch manually through controller

Optional external control via 0/4 – 20 mA and potential-free contacts with pulse step-up and step-down of 32:1 to 1:32 (Division and Multiplication)

Control with internal frequency or

External control through separately priced control cable

Can be connected to:

Water Meter Direct

Boiler Feed Pump

Controller

Recirc On Tower etc.

Pump ProMinent Gamma/X 1602 1604 1009 0708
Max. discharge capacity @ full back pressure 2.3 l/h 3.6 l/h 9 l/h 7.6 l/h
Strokes/min 200 200 200 200
Maximum Working Pressure 16 bar 16 bar 10 bar 7 bar
Maximum Fluid Temperature +20°C +20°C +20°C +20°C
Supply Voltage Universal 100-240 V, 50/60 Hz Universal 100-240 V, 50/60 Hz Universal 100-240 V, 50/60 Hz Universal 100-240 V, 50/60 Hz
Mean Power Consumption 25/30 W 25/30 W 25/30 W 25/30 W
Liquid End Material PVDF PVDF PVDF PVDF
Tubing inlet size 4/6 4/6 4/6 5/8
Tubing outlet size 4/6 4/6 4/6 5/8

Technical Support

If you require additional information or specialist technical support concerning our electric dosing pumps please contact Accepta’s technical support team.

Additional information

Weight 5 kg
Type

Gamma/X 1602, Gamma/X 1604, Gamma/X 0708, Gamma/X 1009, Universal Control Cable, Pump Wall Bracket

Description

Accepta’s range of high performance Prominent Gamma/X dosing pumps are precision manufactured to offer excellent reliability and accurate dosing control of liquids.

Prominent dosing pumps offer external control of the pump output by automatically varying the frequency or number of strokes the pump makes per minute.

The pumps control signal may be by external pacing pulses from a water meter or pH controller with the ability to multiply or divide the pulsed signal.

The gamma/ X solenoid diaphragm metering pump is user-friendly and has a long service life. A sophisticated solenoid control system measures the back pressure present, protects the system from overload and ensures uniform dosing regardless of pressure. In addition, the gamma/ X detects and compensates for air in the dosing head.

Prominent Gamma/X Spec Sheet

 

Prominent Gamma/X Pump Manual

 

Our pumps are supplied fitted with PVDF liquid ends and PTFE seals. This is the most chemically compatible liquid end and is recommended in most cases. Below is the chemical resistance list in case you want to check compatibility with your chemical.

Chemical Resistance List

 

Prominent pumps come with:

Injection fitting (NRV)

Suction foot (NRV)

Suction tube 2m

Injection tube 2m

Powered ON/OFF or Switch manually through controller

Optional external control via 0/4 – 20 mA and potential-free contacts with pulse step-up and step-down of 32:1 to 1:32 (Division and Multiplication)

Control with internal frequency or

External control through separately priced control cable

Can be connected to:

Water Meter Direct

Boiler Feed Pump

Controller

Recirc On Tower etc.

Pump ProMinent Gamma/X 1602 1604 1009 0708
Max. discharge capacity @ full back pressure 2.3 l/h 3.6 l/h 9 l/h 7.6 l/h
Strokes/min 200 200 200 200
Maximum Working Pressure 16 bar 16 bar 10 bar 7 bar
Maximum Fluid Temperature +20°C +20°C +20°C +20°C
Supply Voltage Universal 100-240 V, 50/60 Hz Universal 100-240 V, 50/60 Hz Universal 100-240 V, 50/60 Hz Universal 100-240 V, 50/60 Hz
Mean Power Consumption 25/30 W 25/30 W 25/30 W 25/30 W
Liquid End Material PVDF PVDF PVDF PVDF
Tubing inlet size 4/6 4/6 4/6 5/8
Tubing outlet size 4/6 4/6 4/6 5/8

Technical Support

If you require additional information or specialist technical support concerning our electric dosing pumps please contact Accepta’s technical support team.

Additional information

Weight 5 kg
Type

Gamma/X 1602, Gamma/X 1604, Gamma/X 0708, Gamma/X 1009, Universal Control Cable, Pump Wall Bracket

Data Sheets & enquires

To request the safety or technical data sheets on this product or simply enquire further about chemical supply please fill out this contact form.

Contact us

Please complete this form and we will be in touch