Dispersant & Penetrant for Cooling Towers & Cooling Water Systems – 6026 Bottle

Packaged in cases containing 4 x 4.1kg bottles.

Each case weighs 16.4kg.

Description

Accepta 6026 is a high performance; highly concentrated solid chemical cooling water dispersant and penetrant, scientifically formulated to aid the prevention and removal of organic materials and foulants from cooling towers and cooling water systems.

Accepta 6026 is engineered to supplement cooling system inhibitor/dispersants and biocides to maintain clean surfaces in cooling towers and heat transfer equipment.

Accepta 6026 works to penetrate the matrix of organic surface deposits which are broken up and then disperse. Accepta 6026 can also be used as a general corrosion inhibitor and cleaner for heavily fouled systems.

Accepta recommended that Accepta 6026 is used in conjunction with Accepta biocides to help maintain a clean system.

Accepta 6026 is available in fully recyclable plastic bottles each containing 4.1kg of concentrated solid chemical.

Accepta 6026 is packaged in cases containing 4 x 4.1kg bottles.

Each case weighs 16.4kg.

Product Benefits

  • Innovative solid chemical technology
  • High-performance cooling system dispersant and penetrant
  • Supplements cooling system inhibitor/dispersants and biocides to maintain clean surfaces in heat transfer equipment and cooling towers
  • Can also be used as a general corrosion inhibitor and cleaner for heavily fouled systems
  • Significant safety improvements
  • Easy to handle, simple to dose
  • Environmentally friendly
  • Reduces carbon footprint
  • Significant space savings

Product Properties

Appearance: White amorphous solid
Odour: Slight characteristic odour
Bulk density: 898 kg/m3
Solubility in water: Complete but dissolves slowly
pH (1% solution): 7.0 – 8.0

*Full details of the product properties are available in the Safety Data Sheet. See below.

Application & Dosage Information

For existing clean surfaces Accepta 6026 should be used 1 to 3 times per week and fed at a rate of 80 -150 ppm.

For systems that have a greater tendency to foul, Accepta 6026 should be used 2 to 3 times per week and fed at a rate of 200 ppm.

For heavily fouled systems, Accepta 6026 should be used daily and fed at a rate of 200 ppm, until the system is clean.

Always feed a biocide to kill bacteria and algae in the system.

When using Accepta 6026 to clean heavily fouled systems, care should be taken to prevent clogging of screens and strainers.

Please note that this product may cause foaming when fed at high levels.

Testing & Control

ATP or colony count test kits suitable for monitoring and controlling the use of Accepta 6026 are available from Accepta.

Feeding

Feed Accepta 6026 using an Accepta board system.

It is always advisable to carry out a ‘Control Of Substances Hazardous to Health’ (COSHH) assessment before use.

For further technical assistance concerning Accepta 6026 please contact Accepta.

Safety, Storage & Handling

For full details concerning safety precautions, storage and handling procedures for this product please refer to the latest Safety Data Sheet. To request the latest MSDS for this product please fill out the form below.






Additional information

Weight 25 kg