CG501 / AT-2536 – Silicate Corrosion Inhibitor for Cooling Water Systems (Soft Water)

You are here:

£261.30 ex. VAT

CG501 also known as AT-2536

Price on Application

Product can be used as a replacement for Accepta 2825 & 2225

Description

CG501 / AT-2536 is a high performance, low toxicity silicate based cooling water corrosion inhibitor scientifically formulated for the treatment and protection of open re-circulating cooling water systems.

CG501 / AT-2536 offers the ideal solution for cooling systems containing naturally soft or artificially soft water.

CG501 / AT-2536 is a proven high performance cooling water treatment product designed for controlling the corrosion of steel, copper and brass.

This technically advanced formulation incorporates phosphonates, silicate, phosphate, polymers and azole.It also contains an effective dispersant, and is stable to chlorine and bromine at the levels normally found in cooling systems.

CG501 / AT-2536 is suitable for soft water systems only.

Product Benefits

  • High performance cooling water treatment
  • Suitable for open re-circulating cooling systems
  • Ideal for systems containing natural or artificial soft water
  • Proven high performer against corrosion of steel, copper and brass
  • Contains an effective dispersant
  • Stable to chlorine and bromine
  • Low toxicity

Product Properties

Fprm: Solution
Colour: Clear
Odour: Slight
pH: 12
Specific gravity: 1.27
Solubility in water: Completely miscible
Decomposition temp: Decomposes on heating
Boiling point:  >100 oC

*Full details of the product properties are available in the Safety Data Sheet. See below.

Application & Dosage Information

CG501 / AT-2536 is suitable for soft water systems only.

When starting up a new system or re-starting an existing system apply a dose of 300 ppm.

CG501 / AT-2536 should be dosed to give 100 – 150 ppm in the system.

Always consider the cooling tower manufacturers control limits.

CG501 / AT-2536 is compatible with most cooling water treatment products.

Testing & Control

Test for phosphonate at 2.4 ppm (as o-PO4) at 100 ppm, using a micro pipette method.

It is always advisable to carry out a ‘Control Of Substances Hazardous to Health’ (COSHH) assessment before use.

For further technical assistance concerning CG501 / AT-2536 please contact Accepta.

Safety, Storage & Handling

For full details concerning safety precautions, storage and handling procedures for this product please refer to the latest Safety Data Sheet.

To request the latest MSDS for this product please fill out the form below.

Additional information

Weight 25 kg
Dimensions 30 × 23 × 47 cm

Description

CG501 / AT-2536 is a high performance, low toxicity silicate based cooling water corrosion inhibitor scientifically formulated for the treatment and protection of open re-circulating cooling water systems.

CG501 / AT-2536 offers the ideal solution for cooling systems containing naturally soft or artificially soft water.

CG501 / AT-2536 is a proven high performance cooling water treatment product designed for controlling the corrosion of steel, copper and brass.

This technically advanced formulation incorporates phosphonates, silicate, phosphate, polymers and azole.It also contains an effective dispersant, and is stable to chlorine and bromine at the levels normally found in cooling systems.

CG501 / AT-2536 is suitable for soft water systems only.

Product Benefits

  • High performance cooling water treatment
  • Suitable for open re-circulating cooling systems
  • Ideal for systems containing natural or artificial soft water
  • Proven high performer against corrosion of steel, copper and brass
  • Contains an effective dispersant
  • Stable to chlorine and bromine
  • Low toxicity

Product Properties

Fprm: Solution
Colour: Clear
Odour: Slight
pH: 12
Specific gravity: 1.27
Solubility in water: Completely miscible
Decomposition temp: Decomposes on heating
Boiling point:  >100 oC

*Full details of the product properties are available in the Safety Data Sheet. See below.

Application & Dosage Information

CG501 / AT-2536 is suitable for soft water systems only.

When starting up a new system or re-starting an existing system apply a dose of 300 ppm.

CG501 / AT-2536 should be dosed to give 100 – 150 ppm in the system.

Always consider the cooling tower manufacturers control limits.

CG501 / AT-2536 is compatible with most cooling water treatment products.

Testing & Control

Test for phosphonate at 2.4 ppm (as o-PO4) at 100 ppm, using a micro pipette method.

It is always advisable to carry out a ‘Control Of Substances Hazardous to Health’ (COSHH) assessment before use.

For further technical assistance concerning CG501 / AT-2536 please contact Accepta.

Safety, Storage & Handling

For full details concerning safety precautions, storage and handling procedures for this product please refer to the latest Safety Data Sheet.

To request the latest MSDS for this product please fill out the form below.

Additional information

Weight 25 kg
Dimensions 30 × 23 × 47 cm

Data Sheets & enquires

To request the safety or technical data sheets on this product or simply enquire further about chemical supply please fill out this contact form.

Contact us

Please complete this form and we will be in touch