CB64 / AT-2347 – Phosphate Polymer Treatment for Steam Boilers

You are here:

£140.00 ex. VAT

Quantity discount tiers

5-8

17%

DISCOUNT

9-16

25%

DISCOUNT

17-31

30%

DISCOUNT

32+

33%

DISCOUNT

Prices are for 25Kg Drums/Kegs. POA for 200kg/IBCs.

Description

CB64 / AT-2347 is a high-performance phosphate polymer-based treatment product scientifically formulated for use in steam boilers.

CB64 / AT-2347 is a blended liquid treatment of polymers and is an ideal treatment for steam boilers using softened make-up water.

CB64 / AT-2347 is effective against iron and phosphate sludges. The organic polymer provides transport of the calcium, magnesium, iron, phosphate and silica through the boiler.

The formation of adherent deposits is prevented, thus increasing the steam production runs, reducing the danger of tube overheating

Product Benefits

  • High-performance polymer for use in steam boilers.
  • Excellent treatment for steam boilers.
  • Effective against iron and phosphate sludges.
  • Increases steam production runs.
  • Reduces danger of tube overheating.

Product Properties

Appearance: Light straw coloured liquid
Density (kg/m3): 1.01 – 1.06
Boiling point: 100 oC

*Full details of the product properties are available in the Safety Data Sheet. See below.

Application & Dosage Information

For Water Tube Boilers

Dosage (ppm) = (Feed water hardness x F) + (Feed water iron x 20)

  • Use factor ‘F’ 23 for boilers up to 35bar
  • Factor ‘F’ 24 for boilers 35-40bar
  • Factor ‘F’26 for boilers 41-44bar
  • Above 44bar use an extra Factor of 1 per 3bar boiler pressure

Control product on phosphate reserve in accordance with BS2486 1997.

  • 0-20bar (Phosphate range 30-70ppm)
  • 21-40 bar (phosphate range 20-50ppm)
  • 41-60bar (phosphate range 20-40ppm)
  • 61-70bar (Phosphate range 15-30ppm)
  • Maximum 70 bar pressure for product

For Shell Boilers

Dosage (ppm) = (Feed water hardness x F) + (Feed water iron x 20).

  • Use Factor ‘F’23 for boiler up to 30bar

Control product on phosphate reserve in accordance with BS2486 1997.

Phosphate range in accordance with the Heat Flux for boiler up to 30bar.

  • Heat flux kW/m2 <300 control phosphate 30-60ppm
  • Heat Flux >300 control phosphate 10-30ppm

Note: Dose CB64 / AT-2347 proportional to the boiler feed water before the boiler feed pump.

Use CB64 / AT-2347 neat and do not mix with amines or oxygen scavengers.

It is always advisable to carry out a ‘Control Of Substances Hazardous to Health’ (COSHH) assessment before use.

Safety, Storage & Handling

For full details concerning safety precautions, storage and handling procedures for this product please refer to the latest Safety Data Sheet. To request the latest MSDS for this product please fill out the form below.

Additional information

Weight 25 kg
Dimensions 30 × 23 × 47 cm

Description

CB64 / AT-2347 is a high-performance phosphate polymer-based treatment product scientifically formulated for use in steam boilers.

CB64 / AT-2347 is a blended liquid treatment of polymers and is an ideal treatment for steam boilers using softened make-up water.

CB64 / AT-2347 is effective against iron and phosphate sludges. The organic polymer provides transport of the calcium, magnesium, iron, phosphate and silica through the boiler.

The formation of adherent deposits is prevented, thus increasing the steam production runs, reducing the danger of tube overheating

Product Benefits

  • High-performance polymer for use in steam boilers.
  • Excellent treatment for steam boilers.
  • Effective against iron and phosphate sludges.
  • Increases steam production runs.
  • Reduces danger of tube overheating.

Product Properties

Appearance: Light straw coloured liquid
Density (kg/m3): 1.01 – 1.06
Boiling point: 100 oC

*Full details of the product properties are available in the Safety Data Sheet. See below.

Application & Dosage Information

For Water Tube Boilers

Dosage (ppm) = (Feed water hardness x F) + (Feed water iron x 20)

  • Use factor ‘F’ 23 for boilers up to 35bar
  • Factor ‘F’ 24 for boilers 35-40bar
  • Factor ‘F’26 for boilers 41-44bar
  • Above 44bar use an extra Factor of 1 per 3bar boiler pressure

Control product on phosphate reserve in accordance with BS2486 1997.

  • 0-20bar (Phosphate range 30-70ppm)
  • 21-40 bar (phosphate range 20-50ppm)
  • 41-60bar (phosphate range 20-40ppm)
  • 61-70bar (Phosphate range 15-30ppm)
  • Maximum 70 bar pressure for product

For Shell Boilers

Dosage (ppm) = (Feed water hardness x F) + (Feed water iron x 20).

  • Use Factor ‘F’23 for boiler up to 30bar

Control product on phosphate reserve in accordance with BS2486 1997.

Phosphate range in accordance with the Heat Flux for boiler up to 30bar.

  • Heat flux kW/m2 <300 control phosphate 30-60ppm
  • Heat Flux >300 control phosphate 10-30ppm

Note: Dose CB64 / AT-2347 proportional to the boiler feed water before the boiler feed pump.

Use CB64 / AT-2347 neat and do not mix with amines or oxygen scavengers.

It is always advisable to carry out a ‘Control Of Substances Hazardous to Health’ (COSHH) assessment before use.

Safety, Storage & Handling

For full details concerning safety precautions, storage and handling procedures for this product please refer to the latest Safety Data Sheet. To request the latest MSDS for this product please fill out the form below.

Additional information

Weight 25 kg
Dimensions 30 × 23 × 47 cm

Data Sheets & enquires

To request the safety or technical data sheets on this product or simply enquire further about chemical supply please fill out this contact form.

Contact us

Please complete this form and we will be in touch