Multi-Use Engineers Test Kit with Photometer

You are here:

Price on Application

Test Kit comes with high-quality Lovibond photometer for high accuracy.

Additional tests are performed by dropper titration and a combined pH, TDS and Conductivity Meter.

  • The Standard Test Kit comes with an MD 610 Photometer of equivalent: Quote ETK006MD
  • We can upgrade your kit to the MD 640 Photometer on request: Quote ETK005MD640

 

Description

Multi-Use Engineers Test Kit with Photometer

Accepta’s high-performance, multi-use engineering test kit (with additional Photometer) has been specially developed for engineers, water treatment professionals; and building services and facilities management specialists involved in the maintenance and management of boilers, cooling and closed water systems.

Accepta’s professional multi-parameter water quality analysis testing kit will allow engineers to perform quick and accurate in-field testing and analysis procedures for an extensive range of important system parameters including conductivity, TDS, pH, alkalinity, bromine, chlorine, hardness, iron, molybdate and more.

Water systems require careful test monitoring to ensure the correct risk management regimes and water treatment programs are maintained at all times. Failure to maintain the correct water system conditions can lead to serious problems, including reduced system efficiency, the build-up of scale, potentially damaging corrosive water conditions, and increased microbiological activity, which may result in the proliferation of Legionella bacteria and the increased risks associated with Legionnaires’ disease.

Accepta’s comprehensive “combined” test kit has been developed as a complete kit, specifically for engineers and water treatment professionals involved with the maintenance and management of cooling water, boiler water systems and closed systems.

The test kit is presented in its own robust carry-case and includes all the equipment and reagents necessary to perform between 100 and 200 tests required to effectively test and monitor boiler, cooling and closed system waters to ensure optimum operating conditions are achieved and maintained.

Multi-Use Engineers Test Kit Contents

 

Contents Range Displayed As
Large Peli Plastic Case complete with foams
MD 600, MD 610 or MD 640 Photometer c/w manual & batteries
6 x 10 ml Glass Cells for MD600, MD 610 to MD 640 Photometer
Refractometer (PEG & MEG) 0 to 60 %
Maestro Electronic Pipette [1.0 ml] c/w 6 tips
2 x 20 ml Leur Lock Syringe
10 ml Leur Lock Syringe
5 ml Standard Syringe
1 ml Standard Syringe
Syringe Filter Holder – Luer Lock ø 25 mm
GF/C Filter Papers ø 25 mm
Filter Papers ø 25 mm 0.45 µm (50 pk)
125 ml Plastic Test Bottle
5/10 ml Tube c/w Screw Top
LED Torch
4 x 65 ml Plastic Test Bottle
Tablet Crusher
Cell Cleaning Brush
White Testing Board
2 x 250 ml Plastic Wide Neck Bottle
250 ml Washer Bottle
250 ml Plastic Beaker
2 x 60 ml Calibration Cup
Combined pH/Conductivity/TDS & Temp Meter
Alkalinity P (Titration)
0 to 2000
mg/l CaCO3
PA1 (65 ml)
Alkalinity Titrant [Cartridge Strength] (65 ml)
Alkalinity M (Titration) 0 to 2000 mg/l CaCO3
TA4 (65 ml) (also uses Alkalinity Titrant)
Alkalinity OH (Titration) 0 to 2000 mg/l CaCO3
PA3 (65 ml) (also uses Alkalinity Titrant & PA1)
Bromine (MD 600, MD 610 or MD 640 Photometer) 0.05 to 13 mg/l Br2
DPD No 1 Tablets (50 pk)
DPD No 3 Tablets (50 pk)
Chloride (Titration) 0 to 2000 mg/l Cl
BC1/CC1 (65 ml)
Chloride Titrant [Cartridge Strength] (65 ml)
Chlorine (MD 600, MD 610 or MD 640 Photometer) 0.01 to 6 mg/l Cl2
Uses same reagents as for Bromine above (DPD No 1 & DPD No 3)
Chlorine Dioxide (MD 600, MD 610 or MD 640 Photometer) 0.02 to 11 mg/l ClO2
DPD Glycine Tablets (50 pk) (also uses DPD No 1)
Hardness Total, (Titration) 0 to 2000 mg/l CaCO3
TH2 (65 ml)
TH5 (65 ml)
Hardness HR Titrant [Cartridge Strength] (65 ml)
Hardness Calcium, (Titration) 0 to 2000 mg/l CaCO3
CH2 (65 ml)
CH1P (20 g) (also requires TH3 & H/TH4/CH3)
Hardness Stop/Go (Drop Test) Hard/Soft
Hardness Stop/Go Solution (65 ml)
Iron HR Soluble & Total (MD 600, MD 610 or MD 640) 0.1 to 10 mg/l Fe
FE6 (65ml)
FE8 (65ml)
Molybdate HR (MD 600, MD 610 or MD 640 Photometer) 1 to 100 mg/l MoO4
Molybdate HR (65 ml)
Nitrite (Titration) 10 to 2000 mg/l NaNO2
N1 (65 ml)
Nitrite Titrant [Cartridge Strength] (65 ml)
Phosphate HR (MD 600, MD 610 or MD 640 Photometer) 5 to 80 mg/l PO4
PB1 (65 ml)
PB2 (65 ml)
Phosphonate (Titration) 0 to 20 mg/l
P1/2 (65 ml)
P3 (65 ml)
P4L (65 ml)
Phosphonate Titrant [Cartridge Strength] (65 ml)
Sulphite (Titration) 0 to 2000 Na2SO3
S1 (40 g)
Sulphite Titrant [Cartridge Strength] (65 ml)
Tannin (Drop Test) 10 to 300
TN1 (40 g)
TN2 (65 ml)
Calibration Solutions for Combined pH, Cond’y & TDS Meter
Standard Conductivity 1413 µs (65 ml)
pH 4 (65 ml)
pH 7 (65 ml)
pH 10 (65 ml)
20% Acetic Acid (65 ml)

Technical Support

If you require additional information or specialist technical support concerning our professional multi-parameter engineer’s test kits please contact Accepta’s technical support team.

Description

Multi-Use Engineers Test Kit with Photometer

Accepta’s high-performance, multi-use engineering test kit (with additional Photometer) has been specially developed for engineers, water treatment professionals; and building services and facilities management specialists involved in the maintenance and management of boilers, cooling and closed water systems.

Accepta’s professional multi-parameter water quality analysis testing kit will allow engineers to perform quick and accurate in-field testing and analysis procedures for an extensive range of important system parameters including conductivity, TDS, pH, alkalinity, bromine, chlorine, hardness, iron, molybdate and more.

Water systems require careful test monitoring to ensure the correct risk management regimes and water treatment programs are maintained at all times. Failure to maintain the correct water system conditions can lead to serious problems, including reduced system efficiency, the build-up of scale, potentially damaging corrosive water conditions, and increased microbiological activity, which may result in the proliferation of Legionella bacteria and the increased risks associated with Legionnaires’ disease.

Accepta’s comprehensive “combined” test kit has been developed as a complete kit, specifically for engineers and water treatment professionals involved with the maintenance and management of cooling water, boiler water systems and closed systems.

The test kit is presented in its own robust carry-case and includes all the equipment and reagents necessary to perform between 100 and 200 tests required to effectively test and monitor boiler, cooling and closed system waters to ensure optimum operating conditions are achieved and maintained.

Multi-Use Engineers Test Kit Contents

 

Contents Range Displayed As
Large Peli Plastic Case complete with foams
MD 600, MD 610 or MD 640 Photometer c/w manual & batteries
6 x 10 ml Glass Cells for MD600, MD 610 to MD 640 Photometer
Refractometer (PEG & MEG) 0 to 60 %
Maestro Electronic Pipette [1.0 ml] c/w 6 tips
2 x 20 ml Leur Lock Syringe
10 ml Leur Lock Syringe
5 ml Standard Syringe
1 ml Standard Syringe
Syringe Filter Holder – Luer Lock ø 25 mm
GF/C Filter Papers ø 25 mm
Filter Papers ø 25 mm 0.45 µm (50 pk)
125 ml Plastic Test Bottle
5/10 ml Tube c/w Screw Top
LED Torch
4 x 65 ml Plastic Test Bottle
Tablet Crusher
Cell Cleaning Brush
White Testing Board
2 x 250 ml Plastic Wide Neck Bottle
250 ml Washer Bottle
250 ml Plastic Beaker
2 x 60 ml Calibration Cup
Combined pH/Conductivity/TDS & Temp Meter
Alkalinity P (Titration)
0 to 2000
mg/l CaCO3
PA1 (65 ml)
Alkalinity Titrant [Cartridge Strength] (65 ml)
Alkalinity M (Titration) 0 to 2000 mg/l CaCO3
TA4 (65 ml) (also uses Alkalinity Titrant)
Alkalinity OH (Titration) 0 to 2000 mg/l CaCO3
PA3 (65 ml) (also uses Alkalinity Titrant & PA1)
Bromine (MD 600, MD 610 or MD 640 Photometer) 0.05 to 13 mg/l Br2
DPD No 1 Tablets (50 pk)
DPD No 3 Tablets (50 pk)
Chloride (Titration) 0 to 2000 mg/l Cl
BC1/CC1 (65 ml)
Chloride Titrant [Cartridge Strength] (65 ml)
Chlorine (MD 600, MD 610 or MD 640 Photometer) 0.01 to 6 mg/l Cl2
Uses same reagents as for Bromine above (DPD No 1 & DPD No 3)
Chlorine Dioxide (MD 600, MD 610 or MD 640 Photometer) 0.02 to 11 mg/l ClO2
DPD Glycine Tablets (50 pk) (also uses DPD No 1)
Hardness Total, (Titration) 0 to 2000 mg/l CaCO3
TH2 (65 ml)
TH5 (65 ml)
Hardness HR Titrant [Cartridge Strength] (65 ml)
Hardness Calcium, (Titration) 0 to 2000 mg/l CaCO3
CH2 (65 ml)
CH1P (20 g) (also requires TH3 & H/TH4/CH3)
Hardness Stop/Go (Drop Test) Hard/Soft
Hardness Stop/Go Solution (65 ml)
Iron HR Soluble & Total (MD 600, MD 610 or MD 640) 0.1 to 10 mg/l Fe
FE6 (65ml)
FE8 (65ml)
Molybdate HR (MD 600, MD 610 or MD 640 Photometer) 1 to 100 mg/l MoO4
Molybdate HR (65 ml)
Nitrite (Titration) 10 to 2000 mg/l NaNO2
N1 (65 ml)
Nitrite Titrant [Cartridge Strength] (65 ml)
Phosphate HR (MD 600, MD 610 or MD 640 Photometer) 5 to 80 mg/l PO4
PB1 (65 ml)
PB2 (65 ml)
Phosphonate (Titration) 0 to 20 mg/l
P1/2 (65 ml)
P3 (65 ml)
P4L (65 ml)
Phosphonate Titrant [Cartridge Strength] (65 ml)
Sulphite (Titration) 0 to 2000 Na2SO3
S1 (40 g)
Sulphite Titrant [Cartridge Strength] (65 ml)
Tannin (Drop Test) 10 to 300
TN1 (40 g)
TN2 (65 ml)
Calibration Solutions for Combined pH, Cond’y & TDS Meter
Standard Conductivity 1413 µs (65 ml)
pH 4 (65 ml)
pH 7 (65 ml)
pH 10 (65 ml)
20% Acetic Acid (65 ml)

Technical Support

If you require additional information or specialist technical support concerning our professional multi-parameter engineer’s test kits please contact Accepta’s technical support team.

Data Sheets & enquires

To request the safety or technical data sheets on this product or simply enquire further about chemical supply please fill out this contact form.

Contact us

Please complete this form and we will be in touch